GetPreparedStuff

Calculator

Power station sizing calculator

Power stations are sold by marketing; they should be bought by math. Pick what you actually need to run, for how long, and the size falls out — battery watt-hours, inverter watts, and the solar array to refill it.

In an apartment or renting? Your case is usually smaller than the default below: fridge + phones + lights lands in the ~1 kWh class, and that station is your generator — fuel generators are not an apartment option (outdoors-only, 20+ feet from the building, no legal fuel storage in most rentals). Uncheck the house loads (freezer, furnace blower) and size for your real list. The apartment guide's power section has the renter framing.
Run it?DeviceWattsHours / dayNotes
Refrigerator Compressor duty cycle ~8 h/day
Chest freezer Compressor duty cycle ~8 h/day
CPAP (no heated humidifier) Planning figure — check your machine label
CPAP (heated humidifier on) Humidifier roughly doubles draw
Oxygen concentrator Continuous load — talk to your supplier about backup plans
Router + modem
LED lights (whole home, modest)
Phone charging (2 phones)
Laptop
Furnace blower (gas furnace) Intermittent run time in cold weather
TV
Daily energy—
Battery you need—90% usable × 85% inverter efficiency on AC
Inverter—Sized for motor startup surge, not just running watts
Solar to refill daily—Daily Wh ÷ sun hours × 1.3

How long common station sizes last on your loads

Station sizeRuntime on your loads

Shareable: your loads live in the page URL. Default example above — fridge + CPAP for 2 days — needs about 3,974 Wh of battery on AC (the inverter takes its cut; the DC path needs 3,378 Wh): that is a 3.6 kWh-class station plus solar, or a 2 kWh station plus daily solar recharging. Its inverter must clear a 490 W startup surge (fridge motor at 3× running watts, plus the CPAP), not just the 228 W running total. This is planning math, not medical advice; for CPAP and oxygen, confirm runtimes with your clinician or equipment supplier.

The formulas (so you can check any sales page)

Stations and gear that fit the math

Preparedness supplies: priority, how much to store, why, and where to shop
ItemPriorityHow muchWhyShop
USB power bank (10,000–20,000 mAh ≈ 37–74 Wh)
Storage
Priority: P0 How much: 1 power bank per person Why: Keeps a phone alive for days of intermittent use — your radio, map and contact list when cell service returns. Capacity in honest units: mAh is measured at the cell’s 3.7 V, so 10,000 mAh ≈ 37 Wh and 20,000 mAh ≈ 74 Wh (mAh × 3.7 ÷ 1,000) — compare power banks in Wh, not mAh. Shop: Check price — USB power bank (10,000–20,000 mAh ≈ 37–74 Wh)

Estimated $15–$35 per power bank (as of Nov 18, 2026)

Headlamp or flashlight per person
Lighting
Priority: P0 How much: 1 light per person — plus spare batteries Why: Hands-free light for every person, including kids. Ready.gov lists a flashlight in the basic kit. Shop: Check price — Headlamp or flashlight per person

Estimated $10–$25 per light (as of Nov 18, 2026)

Portable power station (1–2 kWh class)
Storage
Priority: P1 How much: — Why: Runs a fridge intermittently, charges everything, and covers CPAP for a night or two depending on draw. Size it with watt-hour math, not marketing — Wh = watt-hours, the size of the battery tank: daily Wh × days of autonomy ÷ 0.9 usable for LiFePO4 (lithium iron phosphate, the long-life battery chemistry). Shop: Check price — Portable power station (1–2 kWh class)
Folding solar panel (100–200 W)
Generation
Priority: P1 How much: — Why: Recharges a power station during multi-day outages. Rule of thumb: panel watts ≈ daily Wh ÷ peak sun hours × 1.3. Shop: Check price — Folding solar panel (100–200 W)
Rechargeable AA/AAA system + spare batteries
Batteries & charging
Priority: P1 How much: — Why: Radios, lights and kids’ gear all eat AA/AAAs. A rechargeable system plus a charger that works from USB closes the loop. Shop: Check price — Rechargeable AA/AAA system + spare batteries
Carbon monoxide detector (plug-in with battery backup)
Fuel safety
Priority: P0 How much: 1 detector per household — at minimum — one on every level and outside each sleeping area Why: Generators, stoves and heaters kill quietly in outages. Generators run outdoors, at least 20 feet from the house — never in a garage. Shop: Check price — Carbon monoxide detector (plug-in with battery backup)

Estimated $20–$35 per detector (as of Nov 18, 2026)

Jackery Explorer 1000 v2 (1,070 Wh)
Storage
Priority: P1 How much: — Why: A current 1 kWh-class LiFePO4 station: 1,500 W output, fast AC charging. One of three same-class options on the Best Portable Power Stations page — pick by your calculator result and current deals, not by brand. Shop: Check price — Jackery Explorer 1000 v2 (1,070 Wh)
BLUETTI AC180 (1,152 Wh)
Storage
Priority: P1 How much: — Why: A current 1.1 kWh-class LiFePO4 station with 1,800 W output. Same class as the DELTA 2 and Explorer 1000 v2 — the sizing calculator matters more than the badge. Shop: Check price — BLUETTI AC180 (1,152 Wh)
Anker SOLIX C1000 (1,056 Wh, Gen 1)
Storage
Priority: P1 How much: — Why: The Gen 1 C1000 (1,056 Wh, 1,800 W) can add an expansion battery later — the Gen 2 cannot. If expandability matters, make sure the listing is this Gen 1 ASIN, not the Gen 2. Shop: Check price — Anker SOLIX C1000 (1,056 Wh, Gen 1)
Folding solar panel (100 W class)
Generation
Priority: P2 How much: — Why: The smaller panel class: tops up phones, lights and a small station. It cannot carry a fridge — at 300–400 Wh/day against a fridge’s ~1,200 Wh/day, a 1 kWh station still empties in about a day; fridge duty needs roughly 395 W of panel by the sizing math on the Power Station Sizer. The 220 W class refills roughly twice as fast. Shop: Check price — Folding solar panel (100 W class)

Estimated $90–$170 per panel (as of Nov 18, 2026)

CPAP backup battery (machine-specific)
Medical power
Priority: P1 How much: — Why: A dedicated CPAP battery runs most machines 1–3 nights and sips power a big station wastes on its inverter. Match the adapter to your exact machine, and test it at home before an outage does. Sizing math is on the CPAP power guide. Shop: Check price — CPAP backup battery (machine-specific)
Inverter generator (2,000–2,500 W class)
Fuel
Priority: P2 How much: — Why: For multi-day outages with a fridge or furnace blower, a quiet inverter generator plus a transfer plan beats a wall of batteries. It will not run a well pump: typical well pumps are 240 V hardwired, and this class is 120 V only — wells need a 240 V-capable generator in roughly the 5,000 W class and a transfer switch. Carbon monoxide rules are absolute: outdoors only, 20+ feet from the house, exhaust away from windows. Read the Generator Safety guide before buying. Shop: Check price — Inverter generator (2,000–2,500 W class)
Hearing aid batteries + device batteries
Batteries & charging
Priority: P1 How much: — Why: Hearing aids, glucose monitors and other daily devices each eat a specific battery size. Stock your exact size for your duration tier — sizes are not interchangeable. Shop: Check price — Hearing aid batteries + device batteries