Generator safety
A generator is the most useful and most dangerous machine in an outage. Carbon monoxide from generators kills people after nearly every major storm — almost always in a garage, a porch, or a house with the exhaust pointed the wrong way. The rules below are not fine print.
The non-negotiables
- Outdoors only. At least 20 feet from the house, exhaust pointed away from doors, windows and vents. Not in the garage with the door open. Not on the porch. Not in the basement. Ever.
- CO detectors on every level and outside sleeping areas, battery-backed, tested. If one alarms, get out and call 911 — don't air out and re-enter.
- Never backfeed. Plugging a generator into a wall outlet energizes lines and can kill utility workers and burn your house. Use extension cords to appliances, or a professionally installed transfer switch / interlock.
- Cool before refueling. Hot exhaust + spilled gasoline is a fire with a head start. Let it cool, refuel outdoors, away from ignition sources.
- Keep it dry and grounded: run under an open canopy if it's raining, never with wet hands, per the manufacturer's instructions.
- Fuel storage: approved containers only, in a detached shed or outside — never in the living space. Rotate with stabilizer per the maker, and know your local limits.
Generator vs power station — the honest split
| Power station (battery) | Inverter generator | |
|---|---|---|
| Best at | Silence, indoors, CPAP, phones, fridge cycling for 1–3 days | Multi-day outages, furnace blowers, recharging the battery station fast |
| Fails at | Big motor loads, week-long outages without sun | Noise, fuel logistics, CO discipline, apartments |
| The pair | The resilient setup is both: generator runs a few hours a day to refill the station and run big loads; the station carries the quiet hours and the night. | |
Sizing, briefly
Add the running watts of what must run at once, then check starting watts for motor loads — a fridge surges about 3×, and pumps surge 3–5×. A 2,000–2,500 W inverter generator covers a fridge, furnace blower, lights and charging for most homes — the sizing calculator's inverter number is a good proxy. One load it cannot cover: a typical well pump is 240 V hardwired, and these machines are 120 V only, so no wattage in this class runs one. A well pump needs a 240 V-capable generator in roughly the 5,000 W class on a transfer switch — electrician territory. Bigger is louder, thirstier, and rarely necessary.
Pure sine wave: the quiet requirement
Everything this site recommends — the inverter generators and power stations in the catalog — puts out a pure sine wave, the same clean power the wall gives you. Cheaper modified-sine inverters are the trap: their stepped waveform can make a CPAP buzz or run hot, confuse furnace control boards, and misbehave with other sensitive electronics — usually discovered mid-outage. If you shop outside this site's list, "pure sine wave" on the spec sheet is the line to check before price or wattage.
If the furnace won't fire: neutral bonding
Many inverter generators ship with a floating neutral — the neutral is not bonded to ground. Most appliances never notice, but some furnace control boards check for that bond through a transfer switch and fault out: the generator runs, the blower won't. The fix is bonding the neutral — a neutral-bonding plug in a spare generator outlet, or bonding at the panel. The plug is a five-minute job; anything at the panel is electrician territory. Sort out which your setup needs on a calm weekend, not on outage night.
The generator layer in the catalog
| Item | Priority | How much | Why | Shop |
|---|---|---|---|---|
| Inverter generator (2,000–2,500 W class) Fuel | Priority: P2 | How much: — | Why: For multi-day outages with a fridge or furnace blower, a quiet inverter generator plus a transfer plan beats a wall of batteries. It will not run a well pump: typical well pumps are 240 V hardwired, and this class is 120 V only — wells need a 240 V-capable generator in roughly the 5,000 W class and a transfer switch. Carbon monoxide rules are absolute: outdoors only, 20+ feet from the house, exhaust away from windows. Read the Generator Safety guide before buying. | Shop: Check price — Inverter generator (2,000–2,500 W class) |
| Carbon monoxide detector (plug-in with battery backup) Fuel safety | Priority: P0 | How much: 1 detector per household — at minimum — one on every level and outside each sleeping area | Why: Generators, stoves and heaters kill quietly in outages. Generators run outdoors, at least 20 feet from the house — never in a garage. | Shop: Check price — Carbon monoxide detector (plug-in with battery backup) Estimated $20–$35 per detector (as of Nov 18, 2026) |