A generator is the most useful and most dangerous machine in an outage. Carbon monoxide from generators kills people after nearly every major storm — almost always in a garage, a porch, or a house with the exhaust pointed the wrong way. The rules below are not fine print.

The non-negotiables

Generator vs power station — the honest split

Power station (battery)Inverter generator
Best atSilence, indoors, CPAP, phones, fridge cycling for 1–3 daysMulti-day outages, furnace blowers, recharging the battery station fast
Fails atBig motor loads, week-long outages without sunNoise, fuel logistics, CO discipline, apartments
The pairThe resilient setup is both: generator runs a few hours a day to refill the station and run big loads; the station carries the quiet hours and the night.

Sizing, briefly

Add the running watts of what must run at once, then check starting watts for motor loads — a fridge surges about 3×, and pumps surge 3–5×. A 2,000–2,500 W inverter generator covers a fridge, furnace blower, lights and charging for most homes — the sizing calculator's inverter number is a good proxy. One load it cannot cover: a typical well pump is 240 V hardwired, and these machines are 120 V only, so no wattage in this class runs one. A well pump needs a 240 V-capable generator in roughly the 5,000 W class on a transfer switch — electrician territory. Bigger is louder, thirstier, and rarely necessary.

Pure sine wave: the quiet requirement

Everything this site recommends — the inverter generators and power stations in the catalog — puts out a pure sine wave, the same clean power the wall gives you. Cheaper modified-sine inverters are the trap: their stepped waveform can make a CPAP buzz or run hot, confuse furnace control boards, and misbehave with other sensitive electronics — usually discovered mid-outage. If you shop outside this site's list, "pure sine wave" on the spec sheet is the line to check before price or wattage.

If the furnace won't fire: neutral bonding

Many inverter generators ship with a floating neutral — the neutral is not bonded to ground. Most appliances never notice, but some furnace control boards check for that bond through a transfer switch and fault out: the generator runs, the blower won't. The fix is bonding the neutral — a neutral-bonding plug in a spare generator outlet, or bonding at the panel. The plug is a five-minute job; anything at the panel is electrician territory. Sort out which your setup needs on a calm weekend, not on outage night.

The generator layer in the catalog

Preparedness supplies: priority, how much to store, why, and where to shop
ItemPriorityHow muchWhyShop
Inverter generator (2,000–2,500 W class)
Fuel
Priority: P2 How much: — Why: For multi-day outages with a fridge or furnace blower, a quiet inverter generator plus a transfer plan beats a wall of batteries. It will not run a well pump: typical well pumps are 240 V hardwired, and this class is 120 V only — wells need a 240 V-capable generator in roughly the 5,000 W class and a transfer switch. Carbon monoxide rules are absolute: outdoors only, 20+ feet from the house, exhaust away from windows. Read the Generator Safety guide before buying. Shop: Check price — Inverter generator (2,000–2,500 W class)
Carbon monoxide detector (plug-in with battery backup)
Fuel safety
Priority: P0 How much: 1 detector per household — at minimum — one on every level and outside each sleeping area Why: Generators, stoves and heaters kill quietly in outages. Generators run outdoors, at least 20 feet from the house — never in a garage. Shop: Check price — Carbon monoxide detector (plug-in with battery backup)

Estimated $20–$35 per detector (as of Nov 18, 2026)