Guide · Power
Solar charging for emergencies
A panel's watt rating is its output at solar noon in a lab. Your plan should be built on peak sun hours and honest derating — then solar becomes the thing that turns a 2-day battery into an indefinite system.
Updated 2026-11-18
The one formula
Utah averages roughly 5–6 peak sun hours across the year (less in winter, more in summer). The 1.3 covers angle, heat, cables and the charge controller. The sizing calculator does this arithmetic with your loads.
What panels actually deliver
| Panel | Nameplate | Realistic daily yield (5 PSH) | That runs… |
|---|---|---|---|
| Folding panel, small | 100 W | ~300–400 Wh | Phones, lights, radio, a laptop — or a CPAP for a night, roughly |
| Folding panel, large | 220 W | ~700–900 Wh | The above plus meaningful fridge support with a 1 kWh station |
| Two large panels | 440 W | ~1,400–1,800 Wh | A fridge + CPAP + lights daily load, refilled most sunny days |
Three limits, not one: volts, amps, watts
A station's solar input is not a single wattage number. It is three limits at once, and your wiring has to satisfy all three. EcoFlow's published spec for the DELTA 2 — the station this site reviews — is 11–60 V, 15 A, 500 W max. The voltage that counts against the top of that range is the panel's Voc (open-circuit voltage — what the panel produces with nothing drawing from it, printed on every panel's spec sheet), because that is what the station sees at dawn before charging starts.
Worked with real panels: Renogy's datasheet for its ShadowFlux 200 W rigid panel lists Voc 36.5 V, Isc (short-circuit current) 6.86 A, and a maximum-power point of 31.3 V × 6.38 A. Wire two of them to a DELTA 2:
| Wiring | Voltage check | Current check | Power check | Verdict |
|---|---|---|---|---|
| Series (voltages add) | 2 × 36.5 V = 73.0 V vs 60 V max | 6.86 A vs 15 A ✓ | 400 W vs 500 W ✓ | Fails — over voltage before temperature even enters it |
| Parallel (currents add) | 36.5 V, inside 11–60 V ✓ | 2 × 6.86 A = 13.7 A vs 15 A ✓ | 31.3 V × 12.76 A ≈ 400 W vs 500 W ✓ | Works — the full ~400 W is usable |
Same panels, same station, opposite outcomes — decided by the voltage limit, not the wattage. Note the asymmetry: a controller clips excess current and watts (you lose the surplus, nothing more), but excess voltage is not clipped. Voc over the max input is the one wiring mistake that can damage the input stage, which is why the next section matters.
Cold mornings raise voltage
Panel voltage is rated at STC (standard test conditions: 25 °C / 77 °F cell temperature). As a panel gets colder, its Voc rises — every datasheet prints a temperature coefficient of Voc for exactly this reason. Renogy's ShadowFlux datasheet lists −0.25%/°C; its RSP200D 200 W panel lists −0.28%/°C. The minus sign means voltage climbs as temperature falls.
Worked example, against the same DELTA 2 and its 60 V ceiling. The RSP200D's Voc is 27.0 V, so two in series sit at 2 × 27.0 = 54.0 V at STC — inside the limit, with 6 V to spare. Now do the cold arithmetic for a Utah winter morning:
- At 14 °F (−10 °C): the cells are 35 °C below STC. Rise = 35 × 0.28% = 9.8%. Voc = 54.0 × 1.098 = 59.3 V — still legal, but 5.3 of your 6 spare volts are gone.
- At −4 °F (−20 °C): 45 °C below STC. Rise = 45 × 0.28% = 12.6%. Voc = 54.0 × 1.126 = 60.8 V — over the DELTA 2's maximum, with panels that "fit" on paper all summer.
And the timing is unkind: Voc peaks at first light on a cold, clear morning, when the array is connected but nothing is drawing yet — the panel is sitting at open circuit by definition. The rule: size every string with cold-corrected Voc, using the coldest morning your site actually sees, and keep real headroom under the controller's max PV input voltage. If the corrected number lands within a volt or two of the limit, rewire (parallel instead of series) or drop a panel from the string.
MPPT vs PWM: where the extra watts come from
Between the panels and the battery sits a charge controller, and it comes in two kinds. A PWM (pulse-width modulation) controller is essentially a switch: it connects the panel straight to the battery, so the panel is forced to run at battery voltage. An MPPT (maximum power point tracking) controller is a converter: it lets the panel run at its own best voltage and trades the surplus voltage for extra charging current. Power stations like the DELTA 2 have MPPT built in; the choice is yours when you assemble a component system — a separate battery bank for an RV, cabin or ham shack.
The cost of PWM is arithmetic, not opinion. Take the RSP200D above: its maximum-power point is 22.6 V × 8.85 A = 200 W. Charging a 12 V battery bank at 14.4 V:
- PWM: the panel is clamped to ~14.4 V. Panel current stays near 8.85 A, so you harvest roughly 14.4 × 8.85 ≈ 127 W of a 200 W panel. The other ~36% was voltage you paid for and threw away.
- MPPT: the panel stays at 22.6 V and the converter steps down. Even allowing ~5% conversion loss, 200 × 0.95 ≈ 190 W reaches the battery — about 13.2 A of charge current instead of 8.85 A, roughly 1.5× the harvest from the same panel.
Two situations widen that gap further. Cold weather: the same coefficient that raises Voc also raises the panel's working voltage, so the spread between panel voltage and battery voltage — the part PWM discards and MPPT converts — grows on exactly the bright, cold mornings when panels perform best. Higher-voltage strings: series wiring raises voltage without raising current, which cuts cable losses and lets a small array act big — but a PWM controller cannot use a 48 V array on a 12 V battery at all beyond clamping it; MPPT is what makes string voltage a free choice.
When is PWM acceptable? When there is little voltage gap to recover. The loss is roughly (panel Vmp − battery voltage) ÷ panel Vmp: pair a panel whose maximum-power voltage sits close to your battery's charging voltage, keep the array small, and the watts PWM leaves behind are few in absolute terms. The bigger the array and the higher its voltage relative to the battery, the more MPPT pays for itself — in harvested watt-hours, not adjectives.
Field rules
- Angle beats acreage: face panels at the sun and re-aim twice a day; a flat panel on a driveway can lose a third of its day.
- Shade is binary: one shaded cell string can crater a folding panel's output. Keep the whole face clear.
- Match the window: your station's solar input has a voltage range (e.g. 11–60 V class). Series/parallel wiring must land inside it — on volts, amps and watts, at winter temperatures, per the sections above. Check before the outage, with the manual open.
- Charge while you discharge: pass-through charging is normal for this class; the battery is a buffer, not a bucket you empty then fill.
- Winter honesty: short days, low sun, storms. Solar extends an outage plan; in December it rarely replaces stored energy. Keep the generator conversation for multi-day winter outages.
The solar layer in the catalog
| Item | Priority | How much | Why | Shop |
|---|---|---|---|---|
| Folding solar panel (100–200 W) Generation | Priority: P1 | How much: — | Why: Recharges a power station during multi-day outages. Rule of thumb: panel watts ≈ daily Wh ÷ peak sun hours × 1.3. | Shop: Check price — Folding solar panel (100–200 W) |
| Folding solar panel (100 W class) Generation | Priority: P2 | How much: — | Why: The smaller panel class: tops up phones, lights and a small station. It cannot carry a fridge — at 300–400 Wh/day against a fridge’s ~1,200 Wh/day, a 1 kWh station still empties in about a day; fridge duty needs roughly 395 W of panel by the sizing math on the Power Station Sizer. The 220 W class refills roughly twice as fast. | Shop: Check price — Folding solar panel (100 W class) Estimated $90–$170 per panel (as of Nov 18, 2026) |
| Portable power station (1–2 kWh class) Storage | Priority: P1 | How much: — | Why: Runs a fridge intermittently, charges everything, and covers CPAP for a night or two depending on draw. Size it with watt-hour math, not marketing — Wh = watt-hours, the size of the battery tank: daily Wh × days of autonomy ÷ 0.9 usable for LiFePO4 (lithium iron phosphate, the long-life battery chemistry). | Shop: Check price — Portable power station (1–2 kWh class) |